Maternal
Monitor 120C
Fetal & Maternal Monitor
Features
& Benefits
9
standard parameters: ECG, RESP, NIBP, SPO2, 1-TEMP, PR/HR, FHR, TOCO, FM. - 12.1"
high resolution color TFT LCD display. Simple and friendly operating display interface.
- 9-wafer
impulse ultrasound transducer, configured with special HR self correlation reading
algorithm to ensure correct and reliable fetal heart rate (FHR) measurement
- Large
built-in chargeable battery provides convenience for patient’s moving.
- Playback
and browse function for history waveform and monitor data record.
- Optional
printing output function, alarm triggers printing.
- Auto
double alarm with audible and visible signals.
- Anti-defibrillation,
anti-interference from high frequency electrical knife.
- Pacemaker
detection.
- A
full-synchronistic leads, multi-channel ECG display.
- Indication
of incorrect manipulation and malfunction analysis.
- Unique
accessory management cabinet.
Safety IEC60601-1
Approved, Category 1 BF, CF Type
Dimension
and Weight Dimension:
300mm X 500mm X 350mm G.Weight:
9.0KGS Operation
Environment Temperature:
Working 5~+40ºC Humidity:
Working ≤80% Power:
AC100~240V, 50/60Hz Patient
range: Adult,
Pediatric, Neonate, and Fetus Optional: Thermal
Recorder 
Performance
Specifications: |
Display: |
12.1"
color TFT Rolling
and refreshing waveform display Resolution:
800x600 | | Trace: |
4 waveforms Sweep
speed: 12.5mm/s, 25mm/s, 50mm/s | |
Indicator: |
Power/battery
indicator light QRS
beep and alarm sound | |
Battery: |
Rechargeable
built-in-battery, above 2 hours for continuous working | |
Trend time: |
72 hours |
| Alarm:
| User-adjustable
High, Medium and Low limits 3-level
Audible and visual alarm | |
Recorder: |
Built-in,
thermal array Plethysmogram
waveform: 1 channels Record
mode: manual, on alarm, time-defined Recording
width: 50mm Printing
speed: 25mm/s | | ECG Lead
Mode: | 5-lead,
RA, LA, RL, LL, V | | Lead
selection: | I,
II, II, avR, avL, avF, V, MCL | |
Sweep speed: |
12.5mm/s,
25mm/s, 50mm/s | | Heart
Rate range: | 15-300bpm; |
| Accuracy: |
±1bpm or
±1%, whichever is greater | |
Resolution: |
1bpm |
| Filter |
Surgery
mode: 1-25Hz MonitorMode:0.5-35Hz Diagnostic
mode: 0.05-100Hz | | Scaling
signal: | 1mV,
±3% | | Alarm
range: | 20-250bpm |
| S-T
segment detection: | Measurement
range: -2.0mV~+2.0mV Alarm
Range: -2.0mV~+2.0mV | |
NIBP Operation
mode: | Manual/Automatic |
| Auto
measurement time: | Adjustable
(1~120min) | |
Measurment
Unit: | mmHg/Kpa
selectable | | Measurement
types | Systolic,
Diastolic, Mean | | Over-pressure
Protection | Double
safety protection | | SPO2 Measurement
range | 0~100% |
| Resolution: |
1% |
| Accuracy: |
±2%(80~100%):1-60%
unspecified | | Alarm
Range: | 1~100% |
| RESP: Method: |
Thoracic
impedance | | Measurement
Range: | 1~99rpm |
| Alarm
Range: | 1~99rpm |
| Solution: |
1rpm |
| Accuracy: |
±2rpm |
| TEMP Measurement
Range: | 25~45 |
| Resolution: |
0.1ºC |
| Accuracy: |
±0.1ºC |
| Channel: |
1-channel |
| PR: Measurement
Range: | 15~300bpm |
| Resolution: |
1bpm |
| Accuracy: |
1bpm |
| Alarm
range: | 15~300bpm |
| TOCO Measurement
Range | 0~100
unit | | Non-linearity
tolerance | ±8% |
| Accuracy |
1unit |
| Auto-zero
function | Yes |
| FHR Measurement
range | 60~210BPM |
| Accuracy: |
±2rpm |
| Resolution: |
1bpm |
| Transducer: |
9-wafer
impulse ultrasound transducer | |
Ultrasound
output intensity | <3mW/cm2 |
| Ultrasound
working frequency | 1.0MHz |
| Fetal
movement record | Manual
control button label, Auto fetal movement identification |
|
| 
|