Portable
Ventilator Jogger
 Used
for First-Aid, Ambulance, Emergency situation and patients transport in hospital,
it can be used for pediatric and adult patients. A
button operation, it is simple to use with digital control and precise parameters,
and contains special self test function to ensure the patient’s safe. 1.
Specifications
| Kinds
of modes:
C, A/C, SIMV, SIGH, CPAP, PEEP |
| Parameters |
Range |
Remark |
| Tidal
Volume | 50~2000
ml | Digital
Precise Adjustable | | Respiratory
Rate | 1~100
bpm | Digital
Precise Adjustable | |
O2% |
45~100% |
Digital Precise Adjustable |
| Trigger
Level | -20~0
hpa | Digital
Precise Adjustable | | Peak
Pressure | 0~60
hPa | Digital
Precise Adjustable | | PEEP |
0~20
hPa | Digital
Precise Adjustable | | SIGH |
1~10
times per 100 breath | Digital
Precise Adjustable | 2.
Monitor
| Display |
Range |
| Large
LCD Screen Data Display | Tidal
Volume, O2%, Sigh, Respiratory Rate, Flow, Pressure
(Synchronized Trigger, Peak Airway, CPAP, PEEP ) | |
Large LCD Screen Curve Display |
Airway Pressure Time Waveform
Display | | Alarm
Data Display | High/Low
Airway Pressure Alarm, Lack of Gas/Power Alarm, Parameter
Error | |
Other Display |
Lock, Charge Indicator,
Inspiratory/Expiratory Situation, DC/AC
Power Supply |
3.
Self Test, Alarm and Protection ⑴.
Special Self Test:
| Circuit
Connect Prompt | Remind
the operator to connect the breath circuit correctly to access the using state |
| Sound
Alarm Test | Test
sound alarm, to guarantee the reliability using | |
Gas Pressure Test |
Test gas pressure, remind
operator to ensure the gas pressure supply | |
Internal Battery Capacity
Test | Test
the capacity of the internal battery | |
Circuit Leakage Test |
Test Circuit Leakage, to
lest circuit drop off or leak and unexpected situation to happen |
⑵.
Alarm
| High
Airway Pressure | Low
Airway Pressure | |
Low Battery Voltage Alarm |
Low Gas Pressure |
| Parameter
Error | Silence |
| High
Frequency Alarm | |
- Four operating
modes: CMV, A/CMV, SIMV, SPONT
- Lightweight, durable and simple to use
- Ventilation volume and ventilation frequency can be adjusted in
succession
and separately - LCD graphical display to indicate airway pressure, alarm
limits, tidal volume, mode
- Automatic pressure relief valve for airway
pressure more than 6KPa
- Air-oxygen blender prolongs the operating time
during long-time transportation
- Audiovisual low input pressure alarm and
over input pressure protection
|
VENTILATOR PARAMETERS
Tidal
Volume (at C mode) Flow (atA/C, SIMV mode) Breath Rate %02
Spont Flow Sigh Inspiratory time Trigger Level PIP Silence
ALARMS
AND INDICATORS High Pressure Alarm Limit Low
Pressure Alarm Limit Alarm
Indicator Over
Pressure Relief Main
Circuit Pressure (Paw) | RANGE
50~1200ml Low, Med, High 5~60
bpm, 1~12 bpm for SIMV 45%~90% 0~5
UMin 1
per 0-100 breath cycle 0.5~3 s -10~0
hpa 0~60
hpa 60s
20~-60hpa
(to be set) 2~20hpa (to be set) Flashing Red Indicator <
60 hpa -2~10kPa |
|
ELECTRICAL SPECIFICATIONS INPUT POWER SUPPLY DC
Voltage: 12 V Power : 10VA CHARGER AC Voltage:
100 ~ 240 V, 50/60 Hz Power : 25 VA
PNEUMATIC
SPECIFICATIONS Oxygen Inlet Pressuried Oxygen: 0.40 Mpa, 60 L/min. PHYSICAL
300mm (W) x 140mm (D) x 230mm (H) Weight: 3 Kg |
| | |
|