Multi-Parameter Patient Monitor
MAX-10
10.4" Color TFT LCD Screen

In-hospital applications include emergency, pre-and post-operative care, ambulatory surgery, and intermediate care/step down units, labor and hospital-based special procedure areas.

  • 10.4" wide TFT LCD screen with maximum 9-waveform display. Resolution 800 x480.
  • Can be used to monitor Adult, Paed. Neonates
  • Advanced streamline outline design, portable, compact, lightweight
  • SpO2 Pulse Tone Modulation
  • Easy operation with user friendly menu structure design and rotary dial
  • Protection Against electro surgical interference and defibrillation
  • With function of Arrhythmia and ST segment analysis, drug dose calculation, pacemaker detection
  • Intelligent audio and visual comprehensive alarm
  • Rechargeable high-energy built-in Li-Ion battery
  • 96 hour graphical and tabular trends memory
  • Upto 7-Channel ECG display, Big Character Display, OxyCRG. Trend Table Views
  • Memory storage of upto 500 NIBP measurements, 50-alarm events storage with 120-seconds full disclosure of ECG

Standard Configuration: ECG, HR, SpO2, ST Analysis, Resp, NIBP, 2*Temp, Drug Dose Calculation, built in battery

Optional Configuration: Recorder, 2*IBP



Technical Specifications:

ECG
Patient Type : Adult/Paed/Neonate
Lead: 5-Lead : RA LA. Rl, Ll, V
Lead Selection : I, II. Ill, aVR, aVl, aVF, V
ECG Waveforms : 2 or 6 or 7 waveforms
Gain Selection : x2.5mm!mV, x5.0mm!mV, x10mmlmV, 20mm/mV or auto
Sweep Speed :12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range :Adult. 15-300BPM
Paed or Neonate :15-350BPM
Resolution : 1 BPM
Accuracy : ± 1 % or ± 1 BPM, Whichever is higher
Operation Modes :Diagnostic, Monitoring and Surgery
S- T Segment :YES
Arrhythmia Analysis :YES
Alarms Yes. Audio-visual Alarm event:> recallable
Protection :Withstand 4000VAC/50Hz voltage in Isolation against Electrosurgical Interference and Defibrillation
Non-Invasive Blood Pressure
Method : Oscillometric
Operation Mode : Automatic/Manual/Continuous
Measurment Modes : Systolic/Diastolic/Mean Pressure
Measurement Range: Adult: 10-270mmHg Paed . 1o-200mmHg Neonate : 10-135mmHg Overpressure Protection: Yl:.S
Resolution 1 mmHg
Alarms Systolic/Diastolic/Mean
Pulse Oximetry
Measurement Range 0-100%
Accuracy ± 2 digits. 70-99%. Adult/Paed
± 3 digits. 70-990/. Neonate
Unspecified, Less than 70%

OxyCRG Diagram
Enables the doctor to relate Information of patient rapidly & accurately by displaYing HR RESP and oxygen parameter on same screen

Simultaneous Seven leads ECG display

 
Temperature (Skin or Intra-eavity)

Units

:C or "F Measurement Range 0-50"C

Resolution

:0.1 ·C

Accuracy

: ± 0.1 "C (excludes the sensor)

Channel

: 2-Channels

Alarm Range

0-50 ·C

Respiration Rate (RA·LL Impedance)

Method

: Impedance between RA-Ll

Measurement Range

: Adult 0-120rpm
Paed/Neonate: 0-l50, rpm

Accuracy

+ 2 rpm

Alarm Range

: Adult : 0-120 rpm

Apnea Alarm

: YES

Apnea Delay

:10-40 sec

2-Invasive Blood Pressure (Optional)
Measurement Range: :ISO-300 mmHg
Channel : 2-Channels
Pressure Sensor : Sensitivity: 5uVNlrnmHg
Impedance: +300-+10000 Ohms
Pressure Name : ART. PA. CVP. RAP LAP, ICP
Resolution : 1 mmHg
Accuracy : ± 2 or ± 1 mmHg, whichever IS greater excludes sensor
Alarm Range : -50-300 mmHg
Pulse Rate
Measurement Range: : 18-254 BPM
Alarm Range : : 18-254 BPM
Accuracy : ± 3 BPM
Resolution : 1 BPM
Electrical
Power : 100-240 VAC. 50/60 HL
Battery . Rechargeable Li-ion, 2A!hr provides backup of lIpto 3 hrs
Physical
Dimension : 318 (W) x 152 (D) x 264 (1-1) mm :
Weight : -5 Kg


Big Digit Display
Big digit display format makes reading parameters from a distance easy


Trend Display View







In-hospital applications include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and hospital-based special procedure areas.

  • Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portable
  • Can be used to monitor adult, pediatric & neonate patient
  • Upto eight wave-channel display
  • In-built Rechargeable battery which provides a good backup lime
  • 96 Hours graphical and tabular trends memory
  • With function of arrhythmia analysis, drug dose calculation, pacemaker detection and ST segment analysis.
  • User friendly menu structure with easy to use rotary dial
  • Protection Against electro surgical interference and defibrillation
  • Intelligent audio and visual comprehensive alarm. Volume adjustment possible
  • Central monitoring system for long-distance monitoring, diagnosis, maintenance and software upgrade possible

Standard Configuration: ECG, HR, Sp02' ST Analysis, Resp, NIBP, Temp, Drug Dose Calculation, built in battery
Optional Configuration: Recorder, 2*IBP, CO2


Technical Specifications:

ECG
Input: 5 wires/3 wires ECG cable
Lead selection: I,II,III, aVR, aVL, aVF, V
Gain (mm/mV) : 1/4,1/2, 1, 2, 4 & auto
Frequency response: Diagnosis 0.05 - 100Hz
                                   
Monitor 0.5 - 40 Hz
                                    Surgery 1.0 - 25 Hz
Sweep speed (mm/sec) : 12.5, 25, 50
Heart rate range: 10-300 BPM
Heart rate accuracy: ± 1 % or ± 1 BPM, which is greater
ST segment deviation analysis: -0.8 - +0.8mV
ST accuracy: ±0.02mV
Heart Rate Alarm: Yes

Non-Invasive Blood Pressure (Oscillographic)
Measurement type: adult, pediatric, neonate
Measurement range: Systolic 30~270mmHg

                           Diastolic 10~220mmHg
                                    Mean 20~235mmHg

Accuracy: ± 2% or ± 3mmHg, which is greater
Resolution: 1 mmHg
Protection: over pressure

Pulse Oximetry
SpO2 measurement range: 0 -100 %
Resolution: 1 %
Pulse measurement range: 25- 250BPM
Accuracy: ± 2 %. 70~100%
Resolution: 1 BPM

Physical
Weight: ~ 4.5 Kg
Size: 318mm x 264mm x 152mm



OxyCRG Diagram
Enables the doctor to relate information of patient rapidly & accurately by displaying HR, RESP and oxygen parameter on same screen


Simultaneous Seven leads ECG display

Temperature (Skin or Intra-Cavity) Measurement range: 0~500C Accuracy: ± 0.10C
Resolution: 0.10C
Response time: < 3 min.
Channel: 1 Channel


Respiration Rate (RA-LL Impedance)
Measurement range: 0 - 120 BPM Accuracy: ± 2 BPM
Resolution: 1 BPM

EtC02 (Optional Side Stream Type) Measurement range: 0%-13.1 % (0~99mmHg)
Accuracy: ± 0.3%(< 5% Measurement value)

<10% (> 5% Measurement value) Response Time: 180 ms

2·lnvasive Blood Pressure (Optional) Measurement range: -45~+300mmHg
Channel: 2 channel
Transducer sensitivity: 5uV/V/mmHg, 2%
Unit display: kPa or mmHg selectable

Environment
Operation Storage
Temperature 0- 40·C -20 - 500C
Relative humidity < 85% < 93%

Electrical
Input: 100~240 V AC, 50/60Hz
Consumption: < 70VA
Battery type: Lead-Acid
Battery Operation: ~ 2 hrs





Big Digit Display
Big digit display format makes reading parameters from a distance eas
y


 

Next Page>>

 

<<BACK



About us                 |             Product Range                  |            Enquiry Form                    |             Contact            |             Home