Multipara Monitor MAX-12

In-hospital applications include emergency pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas. Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring

  • 12.1" wide TFT LCD screen with maximum 11-waveform display. Resolution 800 x600.
  • Advanced streamline outline design, portable, compact, lightweight
  • SpO2 Pulse Tone Modulation
  • Easy operation with user friendly menu structure design and rotary dial
  • Protection Against electrosurgical interference and defibrillation and no need to disconnect the monitor from the patient in process of defibrillating.
  • Intelligent audio and visual comprehensive alarm
  • Rechargeable high-energy built-in Li-Ion battery
  • 96 hour graphical and tabular trends memory
  • Can be used to monitor Adult, Paed, Neonates
  • Upto 7-Channel ECG display, Big Character Display, OxyCRG, Trend Table Views.
  • With function of Arrhythmia and ST segment analysis, drug dose calculation, pacemaker detection
  • Memory storage of upto 500 NIBP measurements, 60-alarm events storage with 120-seconds full disclosure of ECG

Standard configuration: ECG, HR, PR, SpO2, ST analysis, Arrhythmia Detection, RESP (RA-LL impedance), NIBP, TEMP*2(surface and rectal type), Drug dose calculation.

Optional configuration: Recorder and 2-IBP, EtCO2

Technical Specifications:

ECG
Patient Type: Adult/Paed/Neonate

Lead: 5-Lead : RA, LA, RL, LL, V

Lead Selection: I, II, III, aVR, aVL, aVF, V

ECG Waveforms: 2 or 6 or 7 waveforms

Gain Selection: x2.5mm/mV, x5.0mm/mV,
x10mm/mV, 20mm/mV or auto

Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range: Adult: 15~300BPM

Paed or Neonate: 15~350BPM

Resolution: 1 BPM

Accuracy: ± 1 % or ± 1 BPM, Whichever is higher

Operation Modes: Diagnostic, Monitoring and Surgery
S-T Segment: YES

Arrhythmia Analysis: YES

Alarms: Yes, Audio-visual, Alarm events recallable

Protection: Withstand 4000VAC/50Hz voltage in

isolation against Electrosurgical

interference and Defibrillation

Respiration

Method: Impedance between RA-LL

Measurement Range: Adult: 0-120rpm

Paed/Neonate: 0-150rpm

Resolution: 1rpm

Accuracy: ± 2 rpm

Alarm Range: Adult: 0-120 rpm

Paed/Neonate: 0-150 rpm

Apnea Alarm: YES
Apnea Delay: 10-40 sec

CO2 (Optional)

Measurement range: 0~99 mmHg

Accuracy: ± 2 mm Hg (0~40 mmHg) Or ±10 % (77~99 mmHg)

NIBP

Method: Oscillometric

Operation: Mode: Automatic/Manual/Continuous

Measurment Modes: Systolic/Diastolic/Mean Pressure

Measurement Range: Adult: 10-270mmHg

Paed: 10-200mmHg

Neonate: 10-135mmHg

Overpressure Protection: YES
Resolution: 1mmHg

Alarms: Systolic/Diastolic/Mean

Temperature:

Units: °C or °F

Measurement Range: 0-50 °C

Resolution: 0.1 °C

Accuracy: ± 0.1 °C (excludes the sensor)

Channel: 2-Channels

Alarm Range: 0-50 °C

SpO2

Measurement Range: 0-100%

Accuracy: ± 2 digits, 70-99%, Adult/Paed

± 3 digits, 70-99%, Neonate

Unspecified, Less than 70%

IBP (Optional)

Measurement Range: -50 – 300 mmHg

Channel: 2-Channels

Pressure Sensor: Sensitivity: 5uV/V/mmHg

Impedance: +300~+10000 Ohms

Pressure Name: ART, PA, CVP, RAP, LAP, ICP

Resolution: 1 mmHg

Accuracy: ± 2 or ± 1 mmHg, whichever is greater

excludes sensor

Alarm Range: -50 – 300 mmHg

Pulse Rate

Measurement Range: 18-254 BPM

Alarm Range: 18-254 BPM

Accuracy: ± 3 BPM

Resolution: 1 BPM

Power: 100~240 VAC, 50/60 Hz

Battery: Rechargeable Li-ion, 2A/hr, provides

backup of upto 2 hrs
Dimension: 318 (W) x 152 (D) x 264 (H) mm

Weight: 5 Kg





 


In-hospital applications include emergency, pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and hospital-based special procedure areas.

  • Advanced streamline outline design, compact, lightweight, in-built handle makes it truly portable
  • Can be used to monitor adult, pediatric & neonate patient
  • Upto eight wave-channel display
  • In-built Rechargeable battery which provides a good backup lime
  • 96 Hours graphical and tabular trends memory
  • With function of arrhythmia analysis, drug dose calculation, pacemaker detection and ST segment analysis.
  • User friendly menu structure with easy to use rotary dial
  • Protection Against electro surgical interference and defibrillation
  • Intelligent audio and visual comprehensive alarm. Volume adjustment possible
  • Central monitoring system for long-distance monitoring, diagnosis, maintenance and software upgrade possible

Standard Configuration: ECG, HR, Sp02' ST Analysis, Resp, NIBP, Temp, Drug Dose Calculation, built in battery
Optional Configuration: Recorder, 2*IBP, CO2


Technical Specifications:

ECG
Input: 5 wires/3 wires ECG cable
Lead selection: I,II,III, aVR, aVL, aVF, V
Gain (mm/mV) : 1/4,1/2, 1, 2, 4 & auto
Frequency response: Diagnosis 0.05 - 100Hz
                                   
Monitor 0.5 - 40 Hz
                                    Surgery 1.0 - 25 Hz
Sweep speed (mm/sec) : 12.5, 25, 50
Heart rate range: 10-300 BPM
Heart rate accuracy: ± 1 % or ± 1 BPM, which is greater
ST segment deviation analysis: -0.8 - +0.8mV
ST accuracy: ±0.02mV
Heart Rate Alarm: Yes

Non-Invasive Blood Pressure (Oscillographic)
Measurement type: adult, pediatric, neonate
Measurement range: Systolic 30~270mmHg

                           Diastolic 10~220mmHg
                                    Mean 20~235mmHg

Accuracy: ± 2% or ± 3mmHg, which is greater
Resolution: 1 mmHg
Protection: over pressure

Pulse Oximetry
SpO2 measurement range: 0 -100 %
Resolution: 1 %
Pulse measurement range: 25- 250BPM
Accuracy: ± 2 %. 70~100%
Resolution: 1 BPM

Physical
Weight: ~ 4.5 Kg
Size: 318mm x 264mm x 152mm



OxyCRG Diagram
Enables the doctor to relate information of patient rapidly & accurately by displaying HR, RESP and oxygen parameter on same screen


Simultaneous Seven leads ECG display

Temperature (Skin or Intra-Cavity) Measurement range: 0~500C Accuracy: ± 0.10C
Resolution: 0.10C
Response time: < 3 min.
Channel: 1 Channel


Respiration Rate (RA-LL Impedance)
Measurement range: 0 - 120 BPM Accuracy: ± 2 BPM
Resolution: 1 BPM

EtC02 (Optional Side Stream Type) Measurement range: 0%-13.1 % (0~99mmHg)
Accuracy: ± 0.3%(< 5% Measurement value)

<10% (> 5% Measurement value) Response Time: 180 ms

2·lnvasive Blood Pressure (Optional) Measurement range: -45~+300mmHg
Channel: 2 channel
Transducer sensitivity: 5uV/V/mmHg, 2%
Unit display: kPa or mmHg selectable

Environment
Operation Storage
Temperature 0- 40·C -20 - 500C
Relative humidity < 85% < 93%

Electrical
Input: 100~240 V AC, 50/60Hz
Consumption: < 70VA
Battery type: Lead-Acid
Battery Operation: ~ 2 hrs





Big Digit Display
Big digit display format makes reading parameters from a distance eas