Infusion
Pump
Volumetric

AFF
SENTINELTM
Multi-Purpose
Volumetric Pump
The
AFF SentinelTM
represents the next generation of medical infusion
technology, offering the "all in one" solution by
unifying various dedicated-treatment infusion pumps
and multi-set capability.
The advanced technology of the AFF SentinelTM
allows for its instant recalibration to suit a wide
variety of standard IV sets, previously a costly
and time-consuming process.
The
AFF SentinelTM
is designed to function in primary applications
that include intensive care units, critical care
units, neonatal units, operating procedures, chemotherapy,
anesthesiology and pain management and is suitable
for home-care use.
•
Comprehensive integration of various dedicated-treatment
infusion pumps
•
Intuitive
default parameters setting
•
IV
line guide mechanism
•
Ergonomic graphic user interface for incredibly
easy use
•
Superior accuracy and safety features
• Multi-language
option
•
Multi-set capability
• Internal
software upgradeable
•
Highly cost effective and versatile
•
Alarm history log
•
Dedicated adult/infant flow rates
•
Sturdy construction for lifelong
•
Large LCD display
•
Unique clamp mechanism preventing flow when set
removed from the pump (optional)
AFF
SentinelTM Technical Specifications
|
Infusion
|
|
|
Flow
Rate
|
1-1,200
ml/ hr in 1ml increments (Adult)
0.1-120
ml/ hr in 0.1ml increments (Infant/ MicroInfusion)
|
|
Infusion
Time
|
1-99.59
hrs
|
|
Accuracy*
|
±5%
using recommended sets
|
|
Volume
Range
|
1-9,999
ml in 1 ml increments (Adult)
0.1-999.9
ml in 0.1 ml increments (Infant)
|
|
KVO
|
1
or 5 ml/hr (Adult)
0.1
ml/hr (Infant)
|
|
Fast
Bolus
|
1-1,200
ml/ hr, Volume: 1-999 ml (Adult)
1-120
ml/ hr, Volume: 1-99.9 ml (Infant)
|
|
|
|
Mechanical
|
|
|
Pumping
Mechanism
|
Peristaltic
|
|
Ultrasonic
Air Detector
|
Accumulative:
25-500µl/ 15 min, Adjustable threshold
|
|
Upstream
Pressure Sensor
|
Adjustable
sensitivity
|
|
Downstream
Pressure Sensor
|
Adjustable
sensitivity
|
|
Pressure
Sensitivity Range
|
0.2-1.2
bar (downstream)
|
|
Door
Clamp
|
IV
set free flow protection when door opens
|
|
IV
Set Requirements
|
Suitable
for use with Infusion Pump: OD = 3.5-5mm,
55-72 Shore A
|
|
Dimensions
|
120
x 195 x 240 mm
|
|
Weight
(net)
|
3.0
Kg (approx.)
|
|
Construction
|
Plastic-
double insulated
|
|
|
|
Alarms
|
Pressure
(occlusion: upstream/ downstream), near end,
infusion complete, KVO, high flow, low flow,
drop sensor, battery low, no power, air in
line/infusion disconnection, door open, system/drive
error, alarm time counter, error-sensors,
real time battery
|
|
|
|
Special
Features
|
|
|
KVO
(Keep Vein Open)
|
Continues
to infuse at a minimal rate to keep the vein
open
|
|
ABS
(Anti Bolus System)
|
Releases
pressure due to bolus buildup
|
|
Fast
Bolus
|
Operator
initiated accelerated infusion
|
|
Purge
|
Clears
IV line of air bubbles
|
|
PC
Connection
|
RS232
socket enables maintenance and parameters
settings using an external PC software interface
|
|
Setting
Protection
|
Secure
settings password protected (for authorized
staff only)
|
|
Alarm
Log
|
Records
crucial alarms
|
|
Languages
|
Programmable
user language interface
|
|
RT
Clock
|
Displays
real time clock
|
|
Tube
Guide Mechanism
|
Keeping
IV set in peristaltic movement
|
|
|
| Display |
Rate
of the infusion, Volume already infused (VINF),
Operating time under the current rate or current
volume. Down stream pressure bar indicator,
Total Volume, Time to end at current rate
and current volume, Volume to be infused (VTBI)
|
| |
|
|
Power
|
|
|
Power
Supply Requirements
|
100-240
VAC, 50/60 Hz, 2 Amp. max.
|
|
Battery
|
Rechargeable
Ni-Metal Hydride 7.2V 3.7 Ahr
|
|
Battery
Operation (at 125 ml/hr)
|
~10
hrs
|
|
Memory
Backup Battery
|
Lithium
CR 1620
|
*
Accuracy is dependent on quality of IV set.
AFF
SERIES VOUMETRIC PUMPS Also Available with Following
Options: PCA: Patient Control Analgesia, TPN: Total
Parenteral Nutrition, Volume Over Time: Automatically
Calculates the flow rate according to Infusion Volume
& Duration, Second Bag: Enables Dual Bag Infusion
with Different Parameters, Anti Free Flow Clamp
Mechanism prevents flow when set is removed from
the pump in addition to the door clamp, Slected
Medicine Display, Remote Alarm Indication: For Alarms
when manual intervention is required.