Photo Theraphy Units

Jaundice in newborn can be best treated by using Photo Therapy especially using special purpose NNPT tubes (Normally 4 NNPT cool blue tubes Phillips Holland make for Photo Therapy Source unit only), made exclusively for treating Hyperbilirubinaemia. The said tubes emit ultra violet radiation with peak radiation of 450 nm. The more number of NNPT Tubes, the more effectiveness which in turn ensure fast reduction Billirubin percentage of the Infant.

Photo Therapy is available in single & double surface version. The overhead source comprises 4 NNPT tubes and 2 white tubes, while under surface Photo Therapy bank of light comprises 2 NNPT tubes and 2 white observation tubes (NNPT tube No. Can be increased as per requirements.)

Both the trolley and source unit can be used in conjunction or separate.

The under surface trolley is mounted on castors with drop down Acrylics side panels and provided with Acrylic baby bed and bubbles mattress.


The source unit can be adjusted to various angles and the bank of light's can be adjusted in upward direction.


The Double Surface version along with warmer source unit makes a "PERFECT DUTE".






Micro Controller Based Intensive Care Double Surface Photo Therapy Jeewak

Comprises:-

  • Four Blue Tubes (Philips Holland Make specially made for treating Hyperbilirubinaemia) with white filter
  • Stainless Steel reflector
  • Height adjustment facility enhances varied usage
  • An aesthetical design to liven up the ambience
  • A rotatable saline stand
  • Multipurpose trolley that can be used with warmer or can be used as a stand alone crib.
  • Under surface photo therapy source with four blue tubes, S.S. reflector, white filter and micro controller

Micro Controller:-

  • Indicates tube usage hour, whenever the unit is put on
  • Photo Therapy Dose Time can be set form 30 minutes to 24 hours in 10 minutes increments.
  • Feed Alarm can be set for 30 minutes to 3 hours in 10 Minutes increments
  • Constant display of set photo therapy time dose & dose received by patient
  • Auto cut off once the set does close is over. Audiovisual indication provided with Auto Mute facility.
  • Audiovisual indication to change the photo therapy tubes after predetermined hours. (Auto Mute facility provided)
  • Alarm provided for Feed, Change Tubes, Dose over with automute facility.