Model
OC5L
FEATURES:
- The
System utilizes PSA (Pressure Swing Absorption)
for oxygen generation.
- Self-contained
system for the production of high concentration
oxygen,
using Molecular Sieve to seperate the oxygen from
the nitrogen in the ambient air.
- Oxygen
is concentrated and redirected for use at front
and Nitrogen is ejected.
- Purity
of Oxygen accords to industry standards.
- OC5L
oxygen concentrator with Oxygen Monitoring LEDs
provides
user with unsurpassed quality & reliability.
- Audio
Alarm System alerts the patient in the event of
power failure ensuring
patient safety.
- Low
consumption of power and low cost of oxygen production.
SPECIFICATIONS
| Oxygen
Output | 5
LPM (litres per minute) | |
Oxygen
Purity | 92%
plus or minus 3% | | Response
Time | 5
minutes to attain maximum purity after initial startup or extended shutdown .
| | Dimensions |
~350mm Wide x 420mm
Long x 650mm High |
| Weight |
41.2 LB (21.0 Kg) |
| Power
Requirements | 220
VAC, 50Hz, 3.5 amps |
| Oxygen
Flux Capacity (L/min) |
Oxygen
Thickness
(%V/V) |
Pressure
(MPa) |
Noise
(dB) |
Power
(W) |
| 5 |
>90 |
0.04 |
<50 |
450 |
| Safety
Alarms and Indication |
No power (alarms
& visual indication) Oxygen concentration below normal (visual indication)
| | Standard
Accessories | One
humidifier Bottle Two Nasal Canula with extension tubing. One air filter
set One Dual Flow Connector | | Other
Models Available | 4lit.,
3lit., 5lit. With in-built nubuliser for simultaneous atomizing therapy. |
OXYGEN
CONCENTRATOR
Oxylive

Features
-
The
system utilizes PSA (Pressure Swing Absorption)
for oxygen generation.
-
Self-contained
system for the production of high concentration
oxygen, using Molecular Sieve to separate the
oxygen from the nitrogen in the ambient air.
-
Oxygen
is concentrated and redirected for use at front
& Nitrogen is ejected.
-
Purity
of Oxygen accords to industry standards.
-
Oxygen
Monitoring Display (OCI) optional.
-
Alarm
System alerts the patient in the event of power
failure ensuring patient safety.
-
Low
consumption of power and low cost of oxygen
production.
-
LCD
Display for total used hours.
Specifications
|
Oxygen
Output
|
5
LPM (litres per minute)
|
|
Oxygen
Purity
|
93%
± 2%
|
|
Response
Time
|
5
minutes to attain maximum purity after initial
startup or extended shutdown
|
|
Dimensions
|
~280W
x 360 L x 580 H (mm)
|
|
Weight
|
33.5
Ib (15.2 Kg)
|
|
Power
Requirements
|
220VAC,
50Hz, 2.8A
|
|
Safety
Alarms and Indication
|
No
Power (alarms & visual indication)
|
|
Standard
Accessories
|
One
humidifier Bottle
Two nasal
Canula with extension tubing
One wheel
set of 4
|
|
Other
Models Available
|
5
lit, with in-built nebuliser for simultaneous
atomizing therapy
|
|
Oxygen
Flux Capacity (L/min)
|
Oxygen
Thickness (% V/V)
|
Pressure
|
Noise
(dB)
|
Power
(W)
|
|
5
|
≥90
|
58.6
Kpa/8.5psi
|
≤40
|
280
|
|